| DC input voltage range |
10-15V |
| DC input voltage (nominal) |
12V |
| Continuous power @ 25°C / 77°F |
1200 VA / 5.3A |
| Surge capability (5 sec., resistive) |
2400 VA / 10.5A |
| Parallel use (to double the power) |
no |
| Parallel with shore/generator (for more power) |
yes |
| Output voltage, adjustable via MasterAdjust software |
230V |
| Output voltage regulation |
±5% |
| Frequency (nominal ± 0,05% crystal controlled) |
50/60 Hz adjustable |
| Output waveform |
true sine wave |
| Max. efficiency |
90% |
| No load consumption (normal mode) |
less than 9W @ 230V |
| No load consumption (economy mode) |
less than 8W @ 208V |
| No load consumption (idle mode) |
0.5W |
| Idle power setting |
40-150 VA |
| Nominal input voltage |
230 V |
| Input voltage range |
180-265 V |
| Frequency |
45-65 Hz |
| Enclosure type and dimensions (hxwxd) |
C3A, 371x318x143 mm / 14.6x12.5x5.6 inch |
| Weight |
8.5 kg / 18.5 lbs |
| Max. charge rate (adjustable) |
60A, @ 14.25V DC |
| Primary AC consumption (full load) |
1000 VA / 4.4A |
| Charge voltage @ 25°C / 77°F |
14.25/13.25V |
| Battery type settings |
open lead / gel / traction / AGM / spiral |
| Second charge output, 3stage |
5A |
| Voltage sense function |
yes, automatic |
| Temperature sensor battery |
6 metre cable and telejack plug delivered as standard |
| Max. current first output |
50A |
| Charge characteristic |
IUoUo 3stage (bulk, absorption, float), temperature compensation 5mV/cell/°C |
| Max. current shortbreak / inverter output |
25A |
| Transfer rate |
10 ms typical, 25 ms maximal |
| Harmonic distortion (max.) |
less than 5% |
| Temperature range |
according specifications: 025°C / 32-77°F, thereafter derating |
| Inverter grounding |
yes, adjustable by DIP switch |
| Forced air cooling |
maintenance free vario fans |
| Remote panel ICC ( M70405000) |
optional |
| Remote APC ( M70405010) |
optional |
| Masterlink/MICC ( M70403105) |
optional |